Programming the Memco Oven/Furnace Controller
Default Set-up


Step Generation for the Memco Oven/Furnace Controller

Enter the information requested below.  You must make a selection for each option.  Enter temperature as degrees F (fahrenheit).  Starting times are calculated from 5:00pm and based on overnight burnouts.  If you want to start the controller right away, when the programming steps are displayed, skip the first step and input remaining steps (ie #2 now becomes #1 and so forth).  Note: to achieve the shortest burnout possible, you should steam dewax your flasks and use Stone Saver in your investment.

To convert celcius (centigrade) to fahrenheit, enter the degrees C here:


What time do you want the flasks to be ready to cast: 

Flask diameter: 
(use the size of the largest flask you will be burning out
if your flask size is not shown, select the size that is closest
to yours)

Flask Casting Temperature: 
Check with your alloy provider to get this temperature.  You may use the
chart below if you are not sure what temperature your flask should be.

Alloy Casting Temp ºC Ratio Metal/Wax Flask Temp ºF
Aluminum 720 2.5 450
Brass 85/15 1120 8.5 1110
Ferrium B 1540 7.7 1600
Yellow Gold 10K 977 11.5 960
White Gold 10K 1149 11.0 1130
Yellow Gold 14K 950 13.0 935
White Gold 14K 1066 12.5 1050
Yellow Gold 18K 996 15.5 985
White Gold 18K 1013 14.5 1000
Sterling Silver 980 10.2 990

Are you steam dewaxing your flasks?   Yes   No

Are you using Stone Saver?   Yes   No

Are you casting stones in place?   Yes   No

Please review the above before submitting